BVMVX - M&T SANNNOUS FLUOBORATE SOLUTION ELECTRONIC GRADE

  • MSDS: BVMVX
  • Manufacturer: ATOTECH USA INC
  • Product Name: M&T SANNNOUS FLUOBORATE SOLUTION ELECTRONIC GRADE
  • National Stock Number: 6810-00N052815
Product Identification

Product ID:M&T SANNNOUS FLUOBORATE SOLUTION ELECTRONIC GRADE
MSDS Date:05/17/1989
FSC:6810
NIIN:00N052815
MSDS Number: BVMVX

Responsible Party
ATOTECH USA INC
SOMERSET, NJ 08875-6768
US

Emergency Phone: 908-302-3550;800-424-9300(CHEMTREC)

Info Phone: 908-302-3550

Cage: ATOTC

Contractor
CHEMCUT CORPORATION
STATE COLLEGE, PA 16803-2299 US

Telephone: 814-234-6550,CHEMTREC 800-424-9300

Cage: 08514

Ingredients

AQUEOUS SOLUTION

Fraction By Weight: >45%

OSHA PEL N/K

ACGIH TLV: N/K


STANNOUS FLUOBORATE

CAS: 13814-97-6

Fraction By Weight: <60%

OSHA PEL N/K

ACGIH TLV: 2 MG/M3 (SN)

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES/SKIN: MAY CAUSE IRRITATION.
INHAL: INHALATION OF DUST/FUMES IS IRRITATING TO RESPIRATORY TRACT.
CHRONIC: EXPOSURE TO DUST/FUMES OF INORGANIC TIN COMPOUND IS KNOWN
TO CAUSE A BENIGN PNEUMOCONIOSIS (STANNOSIS). REPEATED EXPOSURE TO
FLUORIDE CONTAINING DUST MAY CAUSE EXCESSIVE CALCIFICATION OF THE
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: BONES & CERTAIN LIGAMENTS. STIFFNESS
& LIMITATION OF MOTION MAY RESULT.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: IN CASE OF CONTACT, IMMEDIATELY FLUSH EYES W/FLOWING
WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION. SKIN: FLUSH
W/FLOWING WATER FOR 15 MINUTES, THEN WASH AREA W/MILD SOAP & WATER.
CALL MD . INHAL: MOVE EXPOSED INDIVIDUAL TO FRESH AIR. CALL MD.
INGEST: NEVER GIVE FLUIDS OR INDUCE VOMITING IF PATIENT IS
UNCONSCIOUS OR HAVING CONVULSIONS. GIVE MILK OF MAGNESIA.

Fire Fighting

Extinguishing Media:WATER SPRAY, FOAM, CARBON DIOXIDE, DRY CEHMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . AVOID EYE & SKIN CONTACT. DO NOT BREATHE
FUMES OR INHALE MISTS.
Unusual Fire/Explosion Hazard:TEMPERATURES AT AND ABOVE THE BOILING
POINT MAY CAUSE GENERATION OF A TOXIC MIST, BORON TRIFLUORIDE.

Accidental Release

Spill Release Procedures:MAY BE HAZARDOUS TO AQUATIC LIFE IF RELEASED
TO OPEN WATERS. CAREFULLY SWEEP UP MATERIAL AND PLACE IN A SUITABLE
CONTAINER FOR DISPOSAL. AVOID CREATING A DUSTY ATMOSPHERE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NORMAL WAREHOUSE HANDLING AND STORAGE.
Other Precautions:MAY CAUSE IRRITATION. AVOID CONTACT WITH EYES, SKIN &
CLOTHING. AVOID INHALATION OF DUST. HARMFUL IF SWALLOWED. AVOID
BREATHING MIST. FOR INDUSTRIAL USE ONLY. NOT FOR FOOD OR DRUG USE.
DO NOT WEAR CON TACT LENSES.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED DUST AND MIST RESPIRATOR
IF EXPOSURE EXCEEDS THE TLV.
Ventilation:LOCAL EXHAUST IS RECOMMENDED. MECHANICAL (GENERAL) IS
REQUIRED.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKER GOGGLES .
Other Protective Equipment:PROTECTIVE CLOTHING. EMERG EYE WASH AND
DELUGE SHOWER WHICH MEETS ANSI DESIGN CRITERIA . LAUNDER (SUPP
DATA)
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER. OTHER PROT. EQUIP: CONTAMINATED
CLOTHING BEFORE REUSE.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Spec Gravity:1.55
pH:2
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR, COLORLESS LIQUID; ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
REDUCERS. ACID INCOMPATIBLE MATERIAL SUCH AS CYANIDES AND SULFIDES.
Stability Condition to Avoid:MAY REACT VIGOROUSLY WITH STRONG OXIDIZING
AGENTS. AVOID ELEVATED TEMPERATURES.
Hazardous Decomposition Products:STANNOUS FLUORIDE; BORON TRIFLUORIDE
GAS.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
STATE AND LOCAL REGULATIONS . DISPOSE OF MATERIAL AS SOLID WASTE IN
A CLOSED CONTAINER. FOLLOW ALL CHEMICAL POLLUTION CONTROL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.